High Temperature Flares
Ecogas high temperature flares are internally coated with refractory insulation and are equipped with main burner for biogas and pilot ignition burner, equipped with high energy electrical ignitor and UV flame detection system.
This type of flare is designed in order to obtain an high combustion efficiency and consequently CO and NOx very low emission values, considerably beneath the limits required by all the current European laws.
The combustion temperature up to 1200 degree C, the emission check made with continuity and the constant monitoring and regulation of the temperature ensures the optimum flare working in any condition.
The methane amount in biogas can range from 20% to 70% (in volume) and the regulation range of the flow from 5 to 1; it is possible to work even with lower ranges but to detriment of the combustion efficiency.
The flares are equipped with Low Nox gas burner whose geometry ensures an excellent mixing of biogas and air combustion pushed in and automatically regulated by a capacity reduction device shutter.
The adopted security systems include an homologated flame arrestor installed upstream the burner, a relief valve and a block system for high temperature.
An electrical command panelboard automatically manages all the controls necessary for a correct flare working.